Review Article
Open Access

Electromagnetic induction detection techniques for craniocerebral injury: A review

Ruoyu Song
Ruoyu Song
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
,
Tao Xu
Tao Xu
Department of Neurosurgery, Changzheng Hospital, Naval Medical University, Shanghai 200003, P. R. China.
,
Tingting Shi
Tingting Shi
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
,
Xinrui Gui
Xinrui Gui
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
,
Rongguo Yan
Rongguo Yan
yanrongguo@usst.edu.cn
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Address correspondence to
Article notes
Highlights

Rongguo Yan, Department of Biomedical Engineering, School of Health Science and Engineering, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu, Shanghai 200093, P. R. China. Tel: 13370260817. E-mail: yanrongguo@usst.edu.cn.

Received January 5, 2022; Accepted May 7, 2023; Published June 30, 2023
  • An induced current occurs in a conductor as a result of electromagnetic induction. 

  • The use of a magnetic field to generate induced current is known as electromagnetic induction, which can be used to detect craniocerebral injury. 

  • Induced current electrical impedance tomography, magneto-acoustic tomography, and eddy current damping sensors for imaging and detection are reviewed in the paper.

Review Article
Open Access
Electromagnetic induction detection techniques for craniocerebral injury: A review
Ruoyu Song
Ruoyu Song
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
,
Tao Xu
Tao Xu
Department of Neurosurgery, Changzheng Hospital, Naval Medical University, Shanghai 200003, P. R. China.
,
Tingting Shi
Tingting Shi
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
,
Xinrui Gui
Xinrui Gui
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
,
Rongguo Yan
Rongguo Yan
yanrongguo@usst.edu.cn
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Address correspondence to

Rongguo Yan, Department of Biomedical Engineering, School of Health Science and Engineering, University of Shanghai for Science and Technology, No. 516 Jungong Road, Yangpu, Shanghai 200093, P. R. China. Tel: 13370260817. E-mail: yanrongguo@usst.edu.cn.

Article notes
Received January 5, 2022; Accepted May 7, 2023; Published June 30, 2023
Highlights
  • An induced current occurs in a conductor as a result of electromagnetic induction. 

  • The use of a magnetic field to generate induced current is known as electromagnetic induction, which can be used to detect craniocerebral injury. 

  • Induced current electrical impedance tomography, magneto-acoustic tomography, and eddy current damping sensors for imaging and detection are reviewed in the paper.

2023 Jun;1(1):19-26
PDF
On This Page
CITE
Accesses: 4

Abstract

Assessing the severity and prognosis of patients with craniocerebral damage is a major research area in medicine since it is a prevalent clinical disease. Acute craniocerebral injury, a common traumatic condition, is often caused by traffic accidents, collisions, and falls in daily life. Secondary craniocerebral injury refers to symptoms such as brain edema and intracranial hemorrhage after acute craniocerebral injury, which will aggravate the injury. Secondary craniocerebral injury can be avoided by effective and timely treatment, and real-time detection of brain edema and intracranial hemorrhage by non-invasive medical imaging is a solution. Therefore, non-invasive medical imaging technology has recently emerged as a new area of study. A new imaging technology, namely the brain injury detection technology based on electromagnetic induction, has been discovered after years of research on non-invasive detection of brain injury. Initially, electromagnetic induction technology was widely used in metal nondestructive testing. The human body, as a conductor, also has electromagnetic induction, allowing this technology to be used on the human body. This study reviews the technologies for detecting electromagnetic induction in cases of craniocerebral damage, including induced current electrical impedance tomography, magneto-acoustic tomography, and eddy current damping sensors for detection and imaging.

Keywords: Craniocerebral injury, electromagnetic induction, electrical impedance tomography, magneto-acoustic tomography, eddy current damping
Progress in Medical Devices